Sign In | Join Free | My futurenowinc.com
China Sansion Power Electric Co., Ltd. logo
Sansion Power Electric Co., Ltd.
Building A One-stop Service Platform
Verified Supplier

1 Years

Home > Impulse Voltage Generator >

Multi-stage Lightning Impulse Voltage Generator Complete Test Equipment For High Voltage Electrical Apparatus Lightning Surge Insulation Test

Sansion Power Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Multi-stage Lightning Impulse Voltage Generator Complete Test Equipment For High Voltage Electrical Apparatus Lightning Surge Insulation Test

Model Number : SXCY

Impulse Energy : 7.31kJ ~ 320kJ

MOQ : 1 Set

Total Impulse Capacitance : 0.1625~0.0833 μF

Brand Name : Sansion

Output Waveform : Lightning & Switching Impulse Wave

Delivery Time : 30 Working Days

Payment Terms : T/T,L/C

Stage Capacitance : 0.325~0.5 μF

Packaging Details : Plywood Case

Certification : CE/SGS/EMS/ISO 9001

Number of Stages : 1 ~ 24 Stages

Place of Origin : China

Rated Voltage : ±100kV ~ ±4800kV

Contact Now

Product Overview

The SXCY Series Impulse Voltage Generator is designed for high-voltage insulation testing under lightning and switching overvoltage conditions. It is suitable for electrical manufacturers, power utilities, testing laboratories, and research institutions.

The system supports lightning impulse full-wave, chopped-wave, and switching impulse voltage tests. It can generate eight standard waveforms, including lightning impulse, switching impulse, chopped lightning wave, oscillating impulse, steep-front wave, and transformer induced switching wave.

Technical parameters comply with relevant Chinese national standards and IEC standards, providing a comprehensive solution for high-voltage impulse testing.

Feature
  • Complete supporting assembly with a wide range of applicable voltage levels.
  • Low-inductance return circuit minimizes waveform distortion and improves test stability.
  • Band-stop filtering technology enables standard impulse waveforms even with high-capacity test loads, providing excellent load adaptability.
  • High voltage utilization efficiency with convenient waveform adjustment and simple operation.
  • Excellent synchronization performance ensures stable and reliable testing.
  • Constant-current charging with automatic control provides a high level of automation and strong anti-interference capability.
  • Integrated digital waveform analysis and online computer processing improve the accuracy and efficiency of impulse voltage testing.
Specifications
Rated Voltage(kV) Total Impulse Capacitance(μF) Stage Capacitance(μF) Impulse Energy(kJ) Stage Voltage(kV) No. of Stages
±100~±400 0.1625~0.0833 0.325~0.5 7.31~33.74 ±100 1~4
±300~±900 0.1625~0.0833 0.325~0.5 7.31~33.74 ±150 2~6
±1050~±1500 0.0464~0.05 0.325~0.5 25.58~56.25 ±150 7~10
±1600~±2400 0.0625~0.0833 0.5~1 80~240 ±200 8~12
±2800~±3200 0.0357~0.0625 0.5~1 80~240 ±200 14~16
±3600~±4800 0.0278~0.03125 0.5~1 140~320 ±200 18~24
Application

Designed for a wide range of high-voltage power equipment, including power transformers, HV insulators, cables, surge arresters, switchgear, CT/PT, bushings and more. It is widely applied in HV laboratories, third-party testing organizations, electrical equipment manufacturers and power grid research centers for type testing and routine factory testing.

FAQ
  1. What is an Impulse Voltage Generator?
    An Impulse Voltage Generator is high voltage test equipment designed to generate controlled impulse voltages for evaluating the insulation performance of high voltage electrical equipment under lightning and switching overvoltage conditions.
  2. What is an Impulse Voltage Generator used for?
    It is widely used for impulse testing of power transformers, high voltage insulators, cables, surge arresters, switchgear, CT/PT, bushings and other power equipment.
  3. What types of impulse tests can this system perform?
    The SXCF Series can be configured for lightning impulse full-wave tests, chopped-wave tests and switching impulse voltage tests. Different impulse waveforms can be generated according to the test requirements.
  4. What voltage ratings are available?
    The SXCF Series covers multiple voltage levels, including approximately ±100 kV to ±4800 kV configurations. The actual voltage rating and stage number can be selected according to the required test voltage.
  5. How is the impulse generator configured?
    The system consists of impulse capacitors, charging and triggering circuits, wave-shaping components, control equipment and a digital measuring system. The number of stages and energy capacity can be customized for different test applications.

Product Tags:

multi-stage lightning impulse voltage generator

      

high voltage electrical apparatus test equipment

      

lightning surge insulation test equipment

      
Wholesale Multi-stage Lightning Impulse Voltage Generator Complete Test Equipment For High Voltage Electrical Apparatus Lightning Surge Insulation Test from china suppliers

Multi-stage Lightning Impulse Voltage Generator Complete Test Equipment For High Voltage Electrical Apparatus Lightning Surge Insulation Test Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sansion Power Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)