| Sign In | Join Free | My futurenowinc.com |
|
Equipment Type : GIS and GIL high voltage equipment
Delivery Time : 30 Working Days
Capacity Range : 50–2000kVA
Model Number : SXGTU
High Voltage Generation : High voltage transformer step-up + series resonance (power frequency / variable frequency)
MOQ : 1
Voltage Level : 100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV
Brand Name : Sansion Power
Partial Discharge Level : 1–3pC at rated voltage under normal environment
Place of Origin : China
Testing Type : AC withstand voltage testing and partial discharge measurement
Payment Terms : L/C,T/T
Shielded Design : Fully sealed in a shielded space
Packaging Details : Plywood Case
Input Voltage : 0.35–10kV
Certification : CE/SGS/EMS/ISO 9001
SXGTU GIS Partial Discharge and Withstand Voltage Test System
The GIS Partial Discharge and Withstand Voltage Test System is designed for high voltage and large capacity GIS/GIL equipment testing. It is mainly used for AC withstand voltage testing and partial discharge measurement to evaluate insulation performance of gas insulated electrical equipment.
The system is suitable for GIS manufacturers, high voltage laboratories and power equipment testing organizations. The high voltage part is fully sealed in a shielded space to reduce external interference and achieve low partial discharge background during testing.
|
Parameter |
Specification |
|
Product Name |
GIS Partial Discharge and Withstand Voltage Test System |
|
Voltage Level |
100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV |
|
Capacity Range |
50–2000kVA |
|
Input Voltage |
0.35–10kV |
|
Partial Discharge Level |
1–3pC at rated voltage under normal environment |
|
High Voltage Generation Method |
High voltage transformer step-up + series resonance (power frequency / variable frequency) |
Q1: What equipment can be tested by this system?
A: The system is mainly designed for GIS and GIL high voltage equipment testing.
Q2: What tests can this system perform?
A: It can perform AC withstand voltage testing and partial discharge measurement.
Q3: Can the voltage level be customized?
A: Yes, different voltage levels and capacity configurations can be customized according to testing requirements.
Q4: Where is this system applied?
A: It is mainly used in GIS manufacturers, high voltage laboratories and power equipment testing organizations.
|
|
GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure Images |